📖 ~1 min read
Table of contents
Symptom & Impact
Fibre Channel adapter on AIX 7.3 shows ‘Available’ but lspath reports paths Failed.
Environment & Reproduction
SAN fabric port flaps or zoning change isolated one HBA from targets.
Root Cause Analysis
fcs adapter sees light but PLOGI fails to one fabric.
Quick Triage
Run lsdev -Cc adapter | grep fcs and lspath -F’name:path_status:status’.
Step-by-Step Diagnosis
Use fcstat fcsN and errpt -j for adapter health.

Solution – Primary Fix
Re-enable failed paths with chpath -l hdiskN -p fscsiM -s enable.
Still having issues? Our IT Solutions & Services team can diagnose and resolve this for you. Get in touch for a free consultation.

Solution – Alternative Approaches
Disable bad path with chpath -s disable until fabric fixed.
Verification & Acceptance Criteria
lspath shows all paths Enabled and fcstat error counters stop rising.
Rollback Plan
Detach FC adapter with rmdev -dl fcsN -R as emergency removal.
Prevention & Hardening
Maintain dual-fabric zoning and monitor fcstat trends.
Related Errors & Cross-Refs
FCP_ARRAY_ERR2, link down events, MPIO failover delays.
Related tutorial: View the step-by-step tutorial for aix-7.2.
View all aix-7.2 tutorials on the Tutorials Hub →
Browse all common problems & solutions on the Tutorials Hub.
References & Further Reading
AIX Fibre Channel and MPIO administration guide.
Need Expert Help?