Symptom & Impact
VIO SEA flaps between primary and backup repeatedly.
Environment & Reproduction
Shared Ethernet Adapter health check misconfigured or VLAN drift.
Root Cause Analysis
ha_mode and ctl_chan miswired after VIOS upgrade.
Quick Triage
Run entstat -all entN | grep -E ‘Primary|Backup’ on both VIOS.
Step-by-Step Diagnosis
Inspect chdev attrs ha_mode, ctl_chan, jumbo_frames consistency.

Solution – Primary Fix
Set ha_mode=sharing and matching ctl_chan VLAN on both VIOS.