📖 ~1 min read
Table of contents
Symptom & Impact
Storage paths repeatedly transition between active and faulty, causing IO latency spikes.
Environment & Reproduction
Reported on SAN-attached SLES 15 hosts after fabric changes or HBA firmware updates.
Root Cause Analysis
Path checker timeouts and `polling_interval` do not match array recommendations.
Quick Triage
Inspect `multipath -ll` for failed and ghost paths.
Step-by-Step Diagnosis
Check `/etc/multipath.conf` and vendor-specific defaults documentation.

Solution – Primary Fix
Apply array-recommended defaults (path_checker, prio, polling_interval) and reload multipathd.
Still having issues? Our IT Solutions & Services team can diagnose and resolve this for you. Get in touch for a free consultation.

Solution – Alternative Approaches
Failover to a single fabric while replacing failing HBA or cable.
Verification & Acceptance Criteria
All paths show `active ready running` with stable IO and no `device-mapper: multipath` errors.
Rollback Plan
Restore previous multipath config from backup if performance regresses.
Prevention & Hardening
Validate fabric health quarterly and pin to certified HBA firmware.
Related Errors & Cross-Refs
Pairs with `path failed` and `path checker failed` log entries.
Related tutorial: View the step-by-step tutorial for sles-15.
View all sles-15 tutorials on the Tutorials Hub →
Browse all common problems & solutions on the Tutorials Hub.
References & Further Reading
SUSE multipath and SAN vendor integration guides.
Need Expert Help?
If you cannot resolve this yourself, our team offers hands-on Server Management, Managed IT Services, and flexible Support Plans. Contact us today — we respond within one business day.