📖 ~1 min read
Table of contents
Symptom & Impact
Client LPAR sees Failed paths to vscsi adapters and I/O slows.
Environment & Reproduction
Dual-VIOS setup on AIX 7.2 client with one VIOS rebooted or upgraded.
Root Cause Analysis
MPIO path on the rebooted VIOS stays in Failed state after recovery.
Quick Triage
Run lspath on the client and look for Failed entries on vscsiN.
Step-by-Step Diagnosis
Confirm VIOS is up with cluster -list and lsmap -all on the VIOS.

Solution – Primary Fix
Re-enable the path on the client with chpath -l hdiskN -p vscsiN -s enable.
Still having issues? Our IT Solutions & Services team can diagnose and resolve this for you. Get in touch for a free consultation.

Solution – Alternative Approaches
Run cfgmgr on the client if the path was rediscovered after VIOS reboot.
Verification & Acceptance Criteria
lspath shows Enabled on all paths and iostat balances across both VIOS.
Rollback Plan
Disable the recovered path with chpath -s disable if regression appears.
Prevention & Hardening
Stagger VIOS maintenance and validate paths post-reboot with lspath.
Related Errors & Cross-Refs
Often correlates with FSCSI_ERR2 and vscsi link reset entries.
Related tutorial: View the step-by-step tutorial for aix-7.1.
View all aix-7.1 tutorials on the Tutorials Hub →
Browse all common problems & solutions on the Tutorials Hub.
References & Further Reading
IBM Docs: PowerVM MPIO, VIOS maintenance procedures.